Toronto Local Appeal Body
40 Orchard View Blvd, Suite 253
Toronto, Ontario M4R 1B9
2024-06-12
24 117282 S45 18 TLAB
Fortune 8 Real Estate Inc. (Re), 2024 ONTLAB 232
FINAL DECISION AND ORDER
Issuance Date:
June 12, 2024
PROCEEDING COMMENCED UNDER Section 45(12), subsection 45(1) of the Planning Act, R.S.O. 1990, c. P.13, as amended (the "Act")
Appellant(s):
FORTUNE 8 REAL ESTATE INC
Applicant(s):
S. ZHANG
Property Address:
241 FINCH AVE E
COA File No.:
23 233856 NNY (A0626/23NY)
TLAB Case File No.:
24 117282 S45 18 TLAB
Hearing Date(s):
June 4, 2024
Deadline Date for Closing Submissions/Undertakings:
June 5, 2024
Decision Delivered By:
TLAB Panel Member R. Kanter
REGISTERED PARTIES AND PARTICIPANTS:
People Type
First Initial. Last Name
Representative
Owner/Appellant
FORTUNE 8 REAL ESTATE INC
I. Andres
M. Lakatos-Hayward
Applicant
S. Zhang
INTRODUCTION AND CONTEXT
1There is some history prior to this Appeal concerning 241-243 Finch Avenue East (the “Site”) coming before the Toronto Local Appeal Body (the “TLAB”).
2In 2018, a Zoning By-Law Amendment (“ZBA”) application (Application No. 18 250648 NNY 23 OZ) and a Site Plan Control (“SPA”) application (Application No. 18 250662 NNY 23 SA) were submitted concurrently to the City of Toronto to amend the City of Toronto Zoning By-law 569-2013 and the former City of North York Zoning By-Law 7625. The previously proposed Zoning By-law Amendment application consisted of a nine (9) unit townhouse development within two lots, but was later revised to eight (8) units. A ZBA and SPA were required to permit the proposed dwelling type and to develop appropriate standards for the Site.
3In a Final Report dated October 1st and 4th, 2021 Council adopted the following:
a. City Council amend Zoning By-law 7625, as amended, for the lands at 241 to 243 Finch Avenue East substantially in accordance with the draft Zoning By-law Amendment in Attachment 5 to the report (August 23, 2021) from the Acting Director, Community Planning, North York District;
b. City Council amend City of Toronto Zoning By-law 569-2013, as amended, for the lands at 241 to 243 Finch Avenue East substantially in accordance with the draft Zoning By-law Amendment in Attachment 6 to the report (August 23, 2021) from the Acting Director, Community Planning, North York District; and
c. City Council authorize the City Solicitor to make such stylistic and technical changes to the draft Zoning By-law Amendments as may be required.
4Arising from Council’s decision, the City of Toronto enacted site-specific Zoning By-law 893-2021 (the “SSZBL”) for the subject Site. The SSZBL allowed eight
(8) townhouse dwelling units, to a height of 11.22 metres, containing 3 stories. No building was to penetrate a 35-degree angular plane abutting the rear yard setback.
5The SSZBL has been incorporated into the general ZBL 569-2013 (the “ZBL”) in Chapter 900, which contains numerous Exceptions to general by-law provisions.
6As a result of the history set out above, 8 townhouses up to 11.22 m in height penetrating a 35-degree angular plane over the rear yard setback are currently permitted on the Site.
7On February 1, 2024, the Committee of Adjustment refused two minor variances to the development permitted on the Site to allow:
(a) a height of 11.98 m, and
(b) an angular plane penetration of 45 degrees (the “C of A Decision”).
The C of A Decision referred to requested variances to Chapter 900.3.10 (emphasis added) of the ZBL.
8On February 20, 2024, the Owner/Appellant appealed the refusal of the two variances to the TLAB (the “Appealed Variances”)
9On May 20, 2024, Toronto Building issued a Zoning Notice confirming the dimensions of the Appealed Variances, but referred to Chapter 900.3.5 (emphasis added) of the ZBL.
THE LEGISLATIVE AND POLICY FRAMEWORK
10Provincial Interest - S. 2
A decision of the Toronto Local Appeal Body (TLAB) shall have regard to, among other matters, matters of provincial interest, enumerated as (a) – (s) in the Planning Act.
It shall also have regard to the decision made by the Committee of Adjustment to refuse or allow the Requested Variances.
11Provincial Policy – S. 3
A decision of the Toronto Local Appeal Body (TLAB) must be consistent with the 2020 Provincial Policy Statement (PPS) and conform to the Growth Plan for the Greater Golden Horseshoe (Growth Plan) for the subject area.
12Variances – S. 45(1)
In considering the applications for variances from the Zoning By-laws, the TLAB Panel must be satisfied that the applications meet all of the four tests under s. 45(1) of the Act. The tests are whether the variances:
maintain the general intent and purpose of the Official Plan;
maintain the general intent and purpose of the Zoning By-laws;
are desirable for the appropriate development or use of the land; and
are minor.
SUMMARY OF EVIDENCE
13Counsel Lakatos-Hayward called David Igelman to give evidence for the Owner/Appellant. After reviewing his education and experience, I qualified Mr. Igelman as an expert, able to give opinion evidence with respect to land use planning.
14Mr. Igelman introduced three exhibits: Ex. 1 – Document Book;
Ex.2 – Witness Statement; and
Ex. 3 – Revised Zoning Notice for the Site
15Mr. Igelman described the Site and surrounding land uses. He said that Finch Ave. E. was identified as a “Major Street” on Map 3 of the City’s Official Plan, and a “Major Arterial Road” on the City’s Road Classification Map.
16Mr. Igelman also provided a Geographic Neighbourhood Map as directed by the Official Plan, delineating a neighbourhood along the north and south side of Finch Ave. E. from Bayview Ave. in the east to Willowdale Ave, in the west (the “Geographic Neighbourhood”) (Ex. 1 page 275).
17It was Mr. Igelman’s evidence that the Committee of Adjustment refused the Appealed Variances since the Owner/Applicant was attempting to vary a development originally permitted through a SSZBL by variances, rather than via a zoning by-law amendment (Ex. 2, par. 53)
18Mr. Igleman explained the rationale for the Appealed Variances was to provide slightly greater ceiling heights for the occupants of the townhouses. The increase in the intrusion into the angular plane from the rear lot line would allow more height for the rear unit.
19According to Mr. Igelman, there were two distinct types of development in the Geographic Neighbourhood: single-detached dwellings one to two stories in height, and townhouses that are two to three stories in height. Some of the townhouse developments have three stories above integral garages at grade.
20Mr. Igelman said that the townhouse form of development was found throughout the Geographic Neighbourhood. In the immediate context of the Site, townhouse development was found on approximately 50% of the lots.
21Mr. Igelman pointed to a townhouse development immediately west of the Site (Ex. 1 page 348 Photo 58). In response to a question from me, he said that in his opinion, the height of the adjacent townhouses was similar to those proposed on the Site. Although the townhouses were allowed to a maximum of 10 m in height, under the previous by-law, height was measured to the mid-point of the roof, rather than to the peak.
22Mr. Igelman provided photos of other townhouse developments in the Geographic Neighbourhood. He was of the opinion that many of the other existing townhouses were similar in height and massing to the townhouses proposed by the Appealed Variances.
23Mr. Igelman also noted the lots east of the Site were occupied by single family homes. He showed the Tribunal photos of a number of three storey townhouses adjacent to one-story, single detached homes (Ex.1 pages 158, 179, 189-91, 192, 193, 199, 212-216). In his opinion, there was no undue adverse impact resulting from three-storey townhouse development adjacent to one-storey single-family homes, providing appropriate setbacks were maintained.
24Mr. Igelman reviewed the planning instruments applicable to the Appealed Variances.
25He opined that the Appealed Variances are consistent with the Provincial Policy Statement, 2020 (the “PPS”) and conform with the Growth Plan for the Greater Golden Horseshoe, 2020 (the “Growth Plan”).
26Mr. Igelman was of the opinion that the Appealed Variances maintain the general intent and purpose of the Official Plan, since they respect and reinforce the existing physical character of buildings streetscapes and open space. More specifically, they are similar – although not necessarily identical to – the heights, massing, scale, density and dwelling types in the Geographic Neighbourhood. Similar townhouse developments occur throughout the Geographic Neighbourhood, and in the immediate context of the Site.
27Mr. Igelman noted that the Official Plan anticipated that the major Avenues, such as Finch Ave. E., will experience? re-urbanization, in order to create new housing opportunities.
28Mr. Igelman referred briefly to the Central Finch Area Secondary Plan (the CFA Secondary Plan). In his opinion, the Appealed Variances maintained the general intent and purpose of the CFA Secondary Plan. Although it generally restricts heights to 10 m., the height for the Site was increased to 11.22 m through the SS ZBL.
29I asked Mr. Igelman when the CFA Secondary Plan was adopted. Following the Hearing, he replied that it was adopted in 2004 at the latest.
30In his oral evidence, he referred to City Council’s adoption of an Expanding Housing Options in Neighbourhoods Report on May 22, 2024 (the “EHON Report”) and stated that Council now permits townhouses on main streets up to four stories and 13 m in height.
31Mr. Igelman referred to the plans submitted prior to the C of A Decision, and showed that the increased penetration of the angular plane affected only a portion of the roof of the southernmost unit in the proposed development.
32Mr. Igelman opined that the change in the exception number in the Official Plan constituted a very minor change from the application that was before the C of A?
33Mr. Igelman noted that City Planning staff did not object to the Requested Variances.
34I also noted that neither the City nor any adjacent neighbours participated in the Hearing in opposition to the Appealed Variances
ISSES AND ANALYSIS
35This case raises the following key issues:
(a) Can a change originating by way of a SSZBL be further altered by minor variance rather than a zoning by-law amendment?
(b) Do the Appealed Variances maintain the intent and purpose of the official plan?
(c) How much weight should the Tribunal give to evolving policy, compared to other planning instruments such as the CFA Secondary Plan?
a) A SITE-SPECIFIC ZONING BY-LAW CAN BE ALTERED BY MINOR VARIANCES
36Mr. Igelman said that minor variances are subject to the tests set out in the Planning Act, regardless of whether they are variances from a general or a site- specific zoning by-law.
37In his opinion, there is no planning rationale to treat a variance originating from an SS ZBL any differently than a variance from the general provisions of ZBL 569-2013. Regardless of the nature of the document setting out the permitted zoning, an applicant can seek to change it by applying for a variance.
38In his submissions, Mr. Lakatos-Hayward reviewed the history of the Planning Act with respect to minor variances. He noted that there was briefly a prohibition against seeking a minor variance within two years of obtaining a previous variance, which is no longer in effect. He stated that there was no legal prohibition preventing or restricting the Tribunal from considering a variance from a zoning standard which originated in a site-specific zoning by-law.
39I agree with Mr. Igelman’s uncontested expert planning opinion, and Mr. Lakatos-Hayward’s uncontested submission that I have jurisdiction to consider the Appealed Variances, which vary the height and angular plane requirements originally adopted by Council by way of an SSZBL
b) THE APPEALED VARIANCES MAINTAIN THE INTENT AND PURPOSE OF THE OFFICIAL PLAN
40According to Policy 4.1.5 of the Official Plan:
“Development in established Neighbourhoods will respect and reinforce the existing physical character of each geographic neighbourhood, including in particular:
c) prevailing heights (emphasis added), massing, scale, density and dwelling type of nearby residential properties . . .
Lots fronting onto a major street (emphasis added) shown on Map 3 and designated Neighbourhoods in the Official Plan are to be distinguished from lots in the interior of the block adjacent to that street in accordance with Policy 6 in order to recognize the potential for a more intense form of development along major streets to the extent permitted by this Plan . . .is this a quote?
Some geographic neighbourhoods contain a mix of physical characters. In such cases, the direction to respect and reinforce the prevailing physical character will not preclude development whose physical characteristics are not the most frequently occurring but do exist in substantial numbers within the geographic neighbourhood, provided that the physical characteristics of the proposed development are materially consistent with the physical character of the geographic neighbourhood and already have a significant presence (emphasis added) on properties located in the immediate context or abutting the same street in the immediately adjacent block(s) within the geographic neighbourhood.”
41Mr. Igelman’s evidence addressed townhouse heights. He provided a Neighbourhood Variance Research Table (Ex. 1 Page 277. The Table illustrated
ten examples of variances for height exemptions, with a mean increase in height to 9.68 m.
42Mr. Igelman also provided additional quantitative evidence that many if not most of the recent townhouse developments in the Geographic Neighbourhood were characterized by heights similar to those proposed by the Appealed Variances.
43He also submitted that other developments with similar heights preceded the data captured by the Table.
44More significantly, Mr. Igelman provided additional photographic evidence that the heights sought in the Appealed Variances were similar to those found in significant numbers in the Geographic Neighbourhood and on the same block and opposite block of the Site.
45He also provided opinion evidence that the test of respecting and reinforcing the existing physical character requires development to be compatible rather than identical.
46Mr. Igleman provided evidence that the Site is located on a major street recognized by the Plan, and therefore has the potential for a more intense form of development than the single-family homes more typically found in the interior of the neighbourhood.
47Mr. Igleman also provided evidence that the proposed townhouse development exists in substantial numbers in the neighbourhood, has a significant presence on the same block and across from the same block as the Site, and is materially consistent with other townhouse developments in the neighbourhood.
48I accept Mr. Igelman’s uncontested expert evidence that the Appealed Variances maintain the intent and purpose of the official plan
49I also accept Mr. Igelman’s evidence that the Appealed Variances maintain the general intent and purpose of the zoning by-law; are minor; and are desirable for the appropriate development of the land.
c) EVOLVING POLICY SUPPORTS THE APPEALED VARIANCES
50Mr. Igelman referred to evolving planning policy which places greater emphasis on a range and mix of housing forms, including additional residential units, multi- unit housing, and more affordable housing, particularly on main streets.
51The origins of such policies are found in the PPS and Growth Plan, in provisions cited by Mr. Igelman.
52However, this policy has been emphasized by significant recent municipal initiatives, including the EHON Report.
53As noted by Mr. Igelman, City Council has very recently approved policies allowing townhouses up to four stories to a height of 13 metres on main streets. While these policies are subject to appeal to the Ontario Land Tribunal, they provide a clear indication of Council’s evolving policy to encourage townhouses with more stories and increased height on main streets.
54I agree with the evidence of Mr. Igelman and the submissions of counsel that the Appealed Variances, if approved, would result in 3 stories rather than 4, and a height of 11.92 m. rather than 13 metres, which are now permitted by the City as supported in the EHON REPORT.
55I will give more weight in this case to evolving policy in 2024 to encourage intensification on main streets than to the CFA Secondary Plan approved at least 20 years earlier. In this case, the Appealed Variances result in development with less than the permitted number of stories and lower height on the Site than Council now supports.
CONCLUSION
56I find the amendment to the Chapter number in the ZBL from the application before the Committee of Adjustment to be minor, so that the amended application does not require public notice pursuant to S. 45 (18.1.1) of the Planning Act.
57I allow the appeal, and approve the Appealed Variances, subject to the usual condition requiring construction substantially in accordance with the plans and elevations before the Tribunal contained herein.
DECISION AND ORDER
58I order that the appeal of the C of A Decision be allowed, and the Appealed Variances be authorized.
59I further order that the authorization be subject to the following condition, attached to this Final Decision as Attachment 1:
“That the building be constructed substantially in accordance with the plans and elevations prepared by TAES Architects Inc. dated 2023.12.01.”
R. Kanter Panel Member
FINCH
CL OF ROAD
149.51
AVENUE EAST
OFFICIAL PLAN: CENTRAL FINCH AREA SECONDARY PLAN ZONING: RT(X333)
LOT AREA: 1,389 sm / 14,957 sf
ROAD ALLOWANCE BETWEEN LOTS 20 AND 21, CONCESSION 1, EAST OF YONGE STREET
MH
PIN 10023-0341(LT)
LOT FRONTAGE: 28.49 m
6.00 m 1.70 m
UP PRIVATE DRIVEWAY
TOP OF CURB CURB CUT TOP OF CURB
0.30
0.20
LOT AREA AFTER ROAD WIDENING: 1,251 sm / 13,461 sf
BUILDING AREA: 429 SM / 4,613 SF (SECOND FLOOR)
CONCRETE SIDEWALK
IP(OU)
15.54
(D1,PL2&S)
N73°21'00"E
NEBWF 0.023N.1M
RENCE BEARING)
EWALK
IB
12.95 m
CONCRETE SIDEWALK
149.76
WV
(D2,PL2&S)
69.03 (CALC'D&M)
IB
0.40
LOT COVERAGE: 31%
LOT COVERAGE AFTER ROAD WIDENING: 35%
0.20
BAYWINDOW
GROUND FLOOR-THIRD FLOOR
GFA: 1,341 sm / 14,433 sf
SSIB (1782) 0.07E
PIL 0.05W 5.81
3.9 m
3.90 m
6.6 m 1.8 m
SOD
C.P.
9.10 m
GARAGE/BASEMENT
UNIT A1
0.6 m
+149.81
Bike Parking.73
PORCH
NUMBER OF UNITS: 8 3 BEDROOMS
GARAGE AREA: 171 sm
FFE = 151.13
1 1 .501.25 m
149.79
FSI (FLOOR SPACE INDEX):
GARAGE = 149.80 UNIT A2
1,341/1,389=1.0 (1 PERMITTED)
FFE = 151.13 2.10 m
GARAGE = 149.65 PORCH
UNIT A3 1.07 2.18 m
No. 24
1 STOREY BRICK DWEL DSE=151.0
GSE=149.7
ROOF=155. (TIES TO BR
BUILDING HEIGHT: 10.00 m BUILDING SETBACK:
NORTH (FRONT YARD): 2.00 m
SOUTH (REAR YARD): 9.5 m
WEST (SIDE YARD): 9.5 m
E. FACE OF WALL
0.12W
UNIT A4
UNIT A5
FFE = 151.13
2.10 m PORCH
1.24
EAST (SIDE YARD): 6.0 m
PARKING: 16 RESIDENTS + 1 VISITOR
TOTAL FRONT YARD AREA AFTER ROAD WIDENING: 51.3 SM
HEAVY DU
GARAGE = 149.50
2.10 m
PIN 10069-
FRONT YARD SOFT LANDSCAPE AREA
AFTER ROAD WIDENING: 33.9 SM (INCLUDES ONLY SODDED AREA)
ASPHALT (REFER TO LANDSCA
E. DRAWING)
1.80 m
E. FACE OF WAL
0.1
PER5M.79 EABLE PAVER (REFER
E. TO LANDSCAPE
UNIT A8 Parking
THIRD FLOOR SETBACK
0.2 1.
UNIT A6
UNIT A7
UNIT A8
SOD
1.5M WALKWAY
PORCH
2.7 m
2.10 m PORCH
2.0 m
0.30
0.30
PERCENTAGE OF FRONT YARD SOFT LANDSCAPING AREA AFTER ROAD WIDENING: 66%
MIN. INTERIOR UNIT LOT AREA: 82 sm / 883 sf
MAX. STAIR AND PORCH ENROACHMENT INTO FRONT YARD: 2.0 m
O.B.C. PART 9, GROUP C 9.10.2.1
DRAWING)
6.00 m 5. m 2.10 m
0.40
TOTAL HARDSCAPE AREA: 562.3 SM
PRIVATE DRIVEWAY
BENCH AREA (REF 1.50 m
TOTAL VEHICULAR ASPHALT AREA: 261 SM
2114
Visitor Parking
A/C scre
WALKWAY
2.18 1.07 m 1.25 m
TOTAL CONCRETE AND UNIT PAVER AREA: 301.3 SM
E. FACE OF WALL
0.16W
9.50 m
13.00 m
PORC LANDSCAPE STRIP
Site Plan 1 : 250
E. FACE OF WALL BOARD FENCE 0.13W
0.20
WEST SETBACK
N73°21'00"E 15.54 (D1,PL2 (RP&M)
Unit A8 Waste StorageEAST SETBACK
N73°21'00"E 12.95
(RP&M) (D2,PL2&S)
0.20
VEHICULAR PAVED AREA: 337 SM TOTAL LANDSCAPE AREA: 631 SM
1 2 3 4 5 6 7 8 9
0.05 m
0' - 2"
C
B
4.13 m
13' - 6 1/2"
LAUNDRY
/UTILITY
UNIT A8
4.00 m
13' - 1 1/2"
UNIT A7
4.00 m
13' - 1 1/2"
UNIT A6
4.00 m
13' - 1 1/2"
UNIT A5
32.38 m
106' - 3"
4.00 m
13' - 1 1/2"
UNIT A4
4.00 m
13' - 1 1/2"
UNIT A3
4.00 m
13' - 1 1/2"
UNIT A2
4.15 m
13' - 7 1/2"
UNIT A1
0.05 m
0' - 2"
C
B
148.38
BEDROOM 02
UP 148.38
UP 3' - UTILITY 3' " 3' " UTILITY- 11" 3' - UTILITY 3' "
4' - 4" 4' - 2" 3' - 4"
UTILIT
11' - 10"
148.38
148.3
148.38
148 8 148.38
U
UNEXCAVATED
1 2
UNEXCAVATED
3
UNEXCAVATED
UNEXCAVATED
32.38 m
106' - 3"
4 5
12' - 3"
6
12' - 3"
UNEXCAVATED
7
12' - 3"
11' - 10"
UNEXCAVATED
8 9
1 00_Basement VA
1 2 3 4 5 6 7 8 9
0.05 m
0' - 2"
4.13 m
13' - 6 1/2"
4.00 m
13' - 1 1/2"
4.00 m
13' - 1 1/2"
4.00 m
13' - 1 1/2"
32.28 m
105' - 11"
4.00 m
13' - 1 1/2"
4.00 m
13' - 1 1/2"
4.00 m
13' - 1 1/2"
4.15 m
13' - 7 1/2"
2.05 m FRONT SETBACK
0.05 m
0' - 2"
ground floor building edge above
C C
4' - 2"
B
UNIT A8
149.47
U 148.38
UNIT A7
149.52
UNIT A6
149.52
UNIT A5
149.52
UNIT A4
149.52
UNIT A3
149.52
UNIT A2
149.67
B
UNIT A1
149.82
1
A 301
1 CAR GARAGE
1 CAR GARAGE1 CAR GARAGE
1 CAR GARAGE1 CAR GARAGE
1 CAR GARAGE1 CAR GARAGE
149.70
148.38148.38
149.70 49.70
148.38148.38
149.70149.70
148.38
DN 149.85 150.00
UP UP
148.38
UP UP
148.38
PORCH ABOVE
PORCH ABOVE
15' - 3"
PORCH ABOVE
15' - 3"
PORCH ABOVE
15' - 3"
DECK ABOVE A
13' - 3"
1
1 01_Garage VA 1 : 150
1.5M WALKWAY
2 3
32.28 m
105' - 11"
4 5 6 7
2 BIKE PARKING
8 9
1 2
4.18 m
13' - 8 1/2"
BALCONY
C
12' - 4"
UNIT A8
B UP
3
4.00 m
13' - 1 1/2"
BALCONY
UNIT A7
4
4.00 m
13' - 1 1/2"
BALCONY
UNIT A6
4.00 m
13' - 1 1/2"
BALCONY
UNIT A5
5
32.38 m
106' - 3"
4.00 m
13' - 1 1/2"
BALCONY
UNIT A
6
4.00 m
13' - 1 1/2"
BALCONY
UNIT A3
7
4.00 m
13' - 1 1/2"
BALCONY
UNIT A2
8 9
4.20 m
13' - 9 1/2"
BALCONY
C
UNIT A1
B
152.24
152.24 P
DN
152.24
152.24P
DN
152.24
152.24UP UP
DN DN
152.39
152.54P
DN
3' - 0"
DN DN
150.98
4' - 2"
A
8' - 11" 3' - 5"
151.151.13
DN
150.98
150.98
DN
150.98
DN
150.98
10" DN
DN
150.98 D150.98
N
DN
150.98
DECK
PORCH
PORCH PORCH
6' - 3"RCHP6' - 3"H
PORCH PORCH
12' - 5"
DN
1 2
1 02_Ground Floor VA 1 : 150
DN DN
3
DN DN
32.38 m
106' - 3"
4 5
DN DN
1.5M WALKWAY
6 7
2 BIKE PARKING
8 9
1
4.18 m
13' - 8 1/2"
2 3
4.00 m
13' - 1 1/2"
4
4.00 m
13' - 1 1/2"
4.00 m
13' - 1 1/2"
5
32.38 m
106' - 3"
6
4.00 m
13' - 1 1/2"
7
4.00 m
13' - 1 1/2"
8
4.00 m
13' - 1 1/2"
9
4.20 m
13' - 9 1/2"
C
BEDROOM 01
BEDROOM 02
BEDROOM 02
BEDROOM 02
BEDROOM 02
BEDROOM 02
BEDROOM 02
C
BEDROOM 02
UP 155.41
155.41
155.41
155.41
155.41 155.41
155.41 B
UNIT A8
UNIT A7 DN
UNIT A6
UNIT A5 DN
DUNIT A4
UNIT A3 DN
DNUNIT A2
UNIT A1 DN
LAUNDRY
155.41
UP
LAUNDRYUNDRY
UP
LAUNDRYUNDRY
UP UP
LAUN LAUNDRY
UP UP
BEDROOM 01 MASTER BEDROOM
BEDROOM 01
BEDROOM 01
BEDROOM 01
BEDROOM 01
BEDROOM 01
BEDROOM 01
A PORCH BELOW
PORCH BELOW
PORCH BELOW
PORCH BELOW
PORCH BELOW A
1 2 3
1 03_Second Floor VA 1 : 150
32.38 m
106' - 3"
4 5 6 7 8 9
"ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT."
1 2 3 4
5 6 7 8 9
DO NOT SCALE DRAWINGS.
CONTRACTOR MUST CHECK & VERIFY ALL DIMENSIONS ON SITE.
THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT.
32.38 m
No.
Issued
Date By
4.18 m
4.00 m
4.00 m
4.00 m 106'
- 3" 4.00 m
4.00 m
4.00 m
4.20 m
1
Building Permit
2022.05.09
SW
13' - 8 1/2"
13' - 1 1/2"
13' - 1 1/2"
13' - 1 1/2"
13' - 1 1/2"
13' - 1 1/2"
13' - 1 1/2"
13' - 9 1/2"
20
Permit Rev01
2022.07.15
SW
25
Variance Application
2023.12.01
SW
C C
STUDY
B
MASTER BEDROOMTER BEDROOMSTER BEDROOMTER BEDROOMSTER BEDROOM TER BEDROOMSTER BEDROOM
B
UNIT A8
DN
UNIT A7
UNIT A6
DN
UNIT A5
DN
UNIT A4
DN
UNIT A3
DN
UNIT A2
DN
UNIT A1
DN
OFFICE
A
MASTER BATH
MASTER BATH MASTER BATH
ID - 3
MASTER BATH
MASTER BATH MASTER BATH MASTER BATH
TAES Architects Inc.
98 SCARSDALE ROAD, TORONTO, ONTARIO, M3B 2R2
T: 416 800 3284 F:416-800-3485
A Townhome
241+243 Finch Avenue,
Toronto
Project Number T2016016
1 2 3 4
1 04_Third Floor VA 1 : 150
5 6 7 8 9
Drawn Scale Checked
Third Floor Plan
Drawing No.
As indicated
2023-12-01
12:12:29 PM
A 105
A
6.00 m EAST SETBACK
B
13.00 m GROUND - 3RD FLOOR
C
9.50 m WEST SERBACK
12
28
BRICK
ASHPHALT SHINGLE
10
1
12
28
+162.01
Top of Roof
+161.03
Ceiling
+160.27
Mid-Point of Roof
+158.54
Top of Eaves
+158.28
Unit 1 - 7 Third Floor
BRICK
STUCCO
SMOOTH STONE
BRICK
1.6 m
+155.41
Unit 1 - 8 Second Floor
+152.54
Unit 1 Ground Floor
+152.39
Unit 2 Ground Floor
+152.24
Unit 3 - 8 Ground Floor
+151.13
First Floor
+150.16
Average Grade (OBC)
+150.03
Est.Grade (By Law 569-2013)
+149.80
1.35 m
1.50 m
1.05 m
2.10 m
13.00 m
1.70 m
6.00 m
Unit 1 Garage
+149.65
Unit 2 Gar1.80 m
+148.38
Unit 1-8 Basement
LANDSCAPE SWALKWAY
PORCH
GROUND - 3RD FLOOR
2ND FL. BALCONY
DRIVEWAY
+1 LANDSCAPE STRIP
Established Grade (CL of Road)
+149.50
1 North Elevation (Street) VA 1 : 100
A3-A7 Garage/A8 Ground FL
C B A
13.00 m
ASHPHALT SHINGLE
BRICK
6.00 m EAST SETBACK
+162.01
Top of Roof
+161.03
Ceiling
+160.27
Mid-Point of Roof
+158.28
Unit 1 - 7 Third Floor
+158.54
Top of Eaves
1 South Elevation (Rear) VA 1 : 100
SMOOTH STONE
SMOOTH STONE
16' - 9"
13.00 m GROUND - 3RD FLOOR
150.28
6.00 m EAST SETBACK
+155.41
Unit 1 - 8 Second Floor
+152.54
Unit 1 Ground Floor
+152.39
Unit 2 Ground Floor
+152.24
Unit 3 - 8 Ground Floor
+151.13
First Floor
+150.16
Average Grade (OBC)
+150.03
Est.Grade (By Law 569-2013)
+149.80
Unit 1 Garage
+149.65
Unit 2 Garage
+149.50
A3-A7 Garage/A8 Ground FL
+149.51
Established Grade (CL of Road)
+148.38
Unit 1-8 Basement
"ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT."
DO NOT SCALE DRAWINGS.
CONTRACTOR MUST CHECK & VERIFY ALL DIMENSIONS ON SITE.
THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT.
No.
Issued
Date By
1 2 3 4 5 6 7 8 9
32.38 m 2.00 m
4.90 m
19 UD
20 Permit Rev01
21 Permit Rev02
23 Permit Rev04
25 Variance Application
2022.07.04 SW
2022.07.15 SW
2022.08.19 SA
2022.10.05 SW
2023.12.01 SW
12 12
3 3
12 12
3 3
+162.01
Top of Roof
+161.03
Ceiling7
+158.54nt of Roof Top of Eaves
150.28
150.34
150.26
ASHPHALT
SHINGLE
BRICK
SMOOTH STONE
150.18
STUCCO
150.10
2.18 m
4.90 m
+158.28
Unit 1 - 7 Third Floor
+155.41
Unit 1 - 8 Second Floor
+152.54
Unit 1 Ground Floor
+152.39
Unit 2 Ground Floor
+152.24
Unit 3 - 8 Ground Floor
+151.13
First Floor
+150.16
Average Grade (OBC)
+150.03
Est.Grade (By Law 569-2013)
TAES Architects Inc.
98 SCARSDALE ROAD, TORONTO, ONTARIO, M3B 2R2
T: 416 800 3284 F:416-800-3485
Townhome
241+243 Finch Avenue,
1 East Elevation (Side) VA 1 : 150
FRONT SETBACK ROAD WIDENING
7.08 m
+149.80
Unit 1 Garage
+149.65
Unit 2 Garage
+149.51
Project Number
Toronto
T2016016
Established Grade (CL of Road)
+149.50
Drawn
Scale
1 : 150
A3-A7 Garage/A8 Ground FL
+148.38
Unit 1-8 Basement
Checked
East Elevation
Drawing No.
2023-12-01
12:12:33 PM
A 203
"ALL DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS ARE THE COPYRIGHT PROPERTY OF THE ARCHITECT AND MUST BE RETURNED UPON REQUEST. REPRODUCTION OF DRAWINGS, SPECIFICATIONS AND RELATED DOCUMENTS IN PART OR IN WHOLE IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT."
DO NOT SCALE DRAWINGS.
CONTRACTOR MUST CHECK & VERIFY ALL DIMENSIONS ON SITE.
THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION UNTIL SIGNED BY THE ARCHITECT.
No.
Issued
Date By
9 8 7 6
5 4 3 2 1
23 Permit Rev04
25 Variance Application
2022.10.05 SW
2023.12.01 SW
4.90 m
2.00 m 32.38 m
9.50 m
ROAD WIDEN FRONT YARD SETBACK
+155.41
Unit 1 - 8 Second Floor
+152.54
Unit 1 Ground Floor
+150.16
STUCCO
BRICK
SMOOTH STONE
STUCCO
STUCCO
GROUND - 3RD FLOOR SETBACK
+162.01
Top of Roof
+161.03
Ceiling
+160.27
Mid-Point of Roof
+158.54
Top of Eaves
+158.28
Unit 1 - 7 Third Floor
+152.39
Unit 2 Ground Floor
+152.24
Unit 3 - 8 Ground Floor
+151.13
First Floor
+150.03
TAES Architects Inc.
98 SCARSDALE ROAD, TORONTO, ONTARIO, M3B 2R2
T: 416 800 3284 F:416-800-3485
Townhome
Average Grade (OBC)
2.18 m
Est.Grade (By Law 569-2013)
FRONT SETBACK
4.90 m 2.00 m
32.38 m GROUND - 3RD FLOOR
+149.80
Unit 1 Gar age
+149.65
Unit 2 Garage
+149.51
+148.38
Unit 1-8 Basement
Project Number
241+243 Finch Avenue,
Toronto
T2016016
1 West Elevation (Side) VA 1 : 150
9.50 m
SETBACK FROM UNIT GROUND - 3RD FLOOR
Established Grade (CL of Road)
+149.50
A3-A7 Garage/A8 Ground FL
Drawn Scale Checked
West Elevation
Drawing No.
1 : 150
2023-12-01
12:12:35 PM
A 204
1 2 3 4 5 6 7 8 9
9.50 m
32.38 m
2.00 m
4.90 m
REAR SETBACK FROM GROUND - 3RD FLOOR FRONT SETBROAD WIDENING
9.50 m
4.18 m 4.00 m 4.00 m
4.00 m
4.00 m 4.00 m
4.00 m
4.20 m
2.00 m 4.90 m
+160.27
Mid-Point of Roof
Top of Eaves
+155.41
Unit 1 - 8 Second Floor
EXIS. AVE GRADE, 150.34M
1.80 m 4.80 m LANDSCAPE STRIP
UNIT 8
UNIT 7
UNIT 6
UNIT 5
UNIT 4
UNIT 3
UNIT 2
UNIT 1
P7
+162.01
Top of Roof
Ceiling
Unit 1 - 7 Third Floor
Unit 1 Ground Floor
Unit 2 Ground Floor
+152.24
Unit 3 -38 Ground Floor
+150.16or
Average Grade (OBC)
+150.03
Est.Grade (By Law 569-2013)
9.50 m
UNIT 8 (2 STOREY)
UNIT 1 - UNIT 7 (3 STOREY)
23' - 2"
0.70 2.10 m
+149.80
REAR YARD SETBACK FROM GROUND TO 3RD FLOOR
1 Section 1 VA 1 : 200
NEW SIDEWALK
Unit 1 Garage
+149.65
Unit 2 Garage
+149.51
Established Grade (CL of Road)
+149.50
A3-A7 Garage/A8 Ground FL
+148.38
Unit 1-8 Basement