Ontario Land Tribunal
Tribunal ontarien de l’aménagement du territoire
ISSUE DATE:
December 02, 2021
CASE NO(S).:
PL210258
PROCEEDING COMMENCED UNDER subsection 45(12) of the Planning Act, R.S.O. 1990, c. P.13, as amended
Applicant and Appellant:
Peter Moroz
Subject:
Minor Variance
Variance from By-law No.:
2008 - 250
Property Address/Description:
57 Hutchison Avenue
Municipality:
City of Ottawa
Municipal File No.:
D08-02-20/A-00336
OLT Case No.:
PL210258
OLT File No.:
PL210258
OLT Case Name:
Moroz v. Ottawa (City)
Heard:
October 20, 2021 by video hearing
APPEARANCES:
Parties
Counsel*/Representative
Peter Moroz
Gregory Meeds* and Lauren Benoit*
Civic Hospital Neighbourhood Association Corporation
Karen Wright
Muge Guher
self-represented
Mathieu Lemay
self-represented
DECISION DELIVERED BY HUGH S. WILKINS AND ORDER OF THE TRIBUNAL
INTRODUCTION
1Peter Moroz (“Appellant”) applied to the City of Ottawa (“City”) Committee of Adjustment for a variance to the City’s Zoning By-law No. 2008-250 (“Zoning By-law”) to facilitate the building of a front-facing garage attached to his existing dwelling located at 57 Hutchison Avenue (“subject property”).
2The Appellant seeks the following variance:
- to permit a front-facing attached garage, whereas s. 139(3)(c) of the Zoning By-law does not permit a front-facing garage as it does not reflect the dominant character as determined by a Streetscape Character Analysis.
3The subject property is designated as General Urban Area under the City’s Official Plan. It is zoned R1QQ (Residential, First Density Zone, Subzone QQ) under the Zoning By-law.
4The Appellant’s application originally sought both the above-noted garage variance as well as a variance for a reduced rear yard setback.
5On April 16, 2021, the City’s Committee of Adjustment refused the requested variances.
6The Appellant appealed the Committee of Adjustment’s decision to the Tribunal.
7Subsequent to the Committee of Adjustment hearing, the Appellant changed his development plans and abandoned his request for the rear yard variance. He decided to only pursue the above-noted variance to permit a front-facing attached garage. It is solely that variance that is before the Tribunal in this proceeding.
8On October 20, 2021, the Tribunal heard the appeal by video hearing.
REQUESTS FOR STATUS
9At the commencement of the hearing, several persons requested Party and Participant status in the proceeding.
10The Civic Hospital Neighbourhood Association Corporation (“CHNA”) requested Party status. It is an incorporated local community association, which has concerns regarding the implementation of the City’s guidelines on development in mature neighbourhoods. It supports the Committee of Adjustment’s decision. None of the Parties objected to the CHNA’s request for status and the Tribunal granted it Party status, as requested.
11Muge Guher also requested Party status. She lives on Kenilworth Street directly behind the subject property. She stated that she has concerns regarding privacy, grading, and other impacts of the proposed variance. She supports the Committee of Adjustment’s decision. The Appellant opposed Ms. Guher’s request for status on the basis that many of her concerns relate to the Appellant’s previously proposed rear-yard variance, which has been abandoned and is not before the Tribunal. Given the location of Ms. Guher’s property abutting the subject property and her concerns regarding impacts arising from the proposed front-facing garage variance, the Tribunal found that she has a genuine and direct interest in the proceeding, she will be impacted by the Tribunal’s decision, and she will assist the Tribunal in making its decision. The Tribunal found that there are reasonable grounds to add Ms. Guher as a Party and the Tribunal granted her Party status, as requested.
12Mathieu Lemay, who lives in the dwelling next door to the Appellant, also requested Party status. He raised concerns regarding the impact of the proposed variance on the streetscape and his property. None of the Parties objected to his request and the Tribunal granted him Party status, as requested.
13Jennifer Walsh, who lives across the street from the subject property, and Peter van Wesenbeeck, who lives closeby, each requested Participant status. None of the Parties objected to their requests and the Tribunal granted them each Participant status, as requested.
ISSUE
14The issue in this appeal is whether or not the proposed variance meets the four tests under s. 45(1) of the Planning Act. These tests are:
does the proposed variance maintain the general purpose and intent of the City’s Official Plan?
does it maintain the general purpose and intent of the Zoning By-law?
is it desirable for the appropriate use of the subject property?
is it minor?
The proposed variance must also be consistent with the Provincial Policy Statement, 2020 (“PPS”). When making its decision, the Tribunal must have regard to the matters of provincial interest set out in s. 2 of the Planning Act and it must have regard to the decision of the Committee of Adjustment and the information considered by it, as required under s. 2.1(1) of the Planning Act.
EVIDENCE, SUBMISSIONS, ANALYSIS AND FINDINGS
15Murray Chown and Robert Sandercott each were qualified to provide opinion evidence in the area of land use planning. Mr. Chown is a land use planner retained by the Appellant and Mr. Sandercott is a land use planner employed by the City who was summoned by the Appellant to provide evidence.
16Karen Wright provided fact evidence on behalf of CHNA and Ms. Guher and Mr. Lemay each provided fact evidence on their own behalves.
Issue 1 Does the proposed variance maintain the general purpose and intent of the City’s Official Plan?
Evidence and Submissions
17Mr. Chown opined that the proposed variance maintains the general purpose and intent of the City’s Official Plan. He stated that the proposed variance facilitates the building of an accessory structure that is permitted under the City’s Official Plan. He stated the proposed garage would be slightly set back from the front of the existing dwelling and the proposed variance would facilitate a compatible development that enhances the community without causing undue adverse impacts on surrounding properties.
18Mr. Sandercott also opined that the proposed variance maintains the general purpose and intent of the City’s Official Plan and that the proposed variance would facilitate a development that is compatible with existing development in the area.
19Ms. Wright stated that the proposed variance does not maintain the general purpose and intent of the City’s Official Plan. She said that detached garages predominate on the street and the proposed variance would result in a development that is not compatible and would not enhance the existing development pattern in the area as required under policy 3.6.1 of the City’s Official Plan.
20Mr. Lemay also stated that the proposed variance does not maintain the general purpose and intent of the City’s Official Plan. He stated that the compatibility policies in policy 3.6.1 are important and that mature neighbourhoods must be protected.
Analysis and Findings
21Based on the evidence and submissions before it, the Tribunal finds that the proposed variance maintains the general purpose and intent of the City’s Official Plan. Policy 3.6.1 of the City’s Official Plan states, in part, that a full range and choice of housing types is permitted in the City’s General Urban Area to meet the needs of people of all ages, incomes, and life circumstances. It also supports development in a manner that enhances and complements and ensures the long-term vitality of existing communities. The Tribunal finds that based on the Appellant’s plans to have the proposed garage set back from the front of the existing dwelling, it will resemble detached garages on the street. The Tribunal finds that attached garages are permitted in the General Urban Area and the proposed variance will satisfy the objectives in policy 3.6.1 in that it will facilitate a development that is compatible with the existing development pattern in the area.
Issue 2 Does the proposed variance maintain the general purpose and intent of the Zoning By-law?
Evidence and Submissions
22Mr. Chown opined that the proposed variance maintains the general purpose and intent of the Zoning By-law. He stated that based on the requirements in s. 140 of the Zoning By-law, the Appellant was required to have a Streetscape Character Analysis conducted to determine whether the proposed front-facing attached garage is permissible. A Streetscape Character Analysis documents the dominant pattern of a streetscape regarding the location and type of driveways, location and size of parking spaces, garages and carports, and orientation of principal entranceways. Under s. 140, the Analysis must examine 21 lots located on the street, including the nearest ten lots on the same side of the street (in the same block), the lot across the street from the property, and the ten lots nearest that lot (again in the same block). Mr. Chown stated that the Appellant had a Streetscape Character Analysis conducted, which determined that less than 50% of the lots assessed in the Analysis have front-facing attached garages. He said that based on this, the subject property lies within “Character Area A” as defined in s. 140 of the Zoning By-law, which does not permit front-facing attached garages. Due to this finding, he stated that the proposed variance was required.
23Mr. Chown noted that several of the lots in the study area have front-facing attached garages. He said the proposed variance would facilitate a garage that is slightly set back from the front of the existing dwelling making it secondary in nature and ensuring that it does not interfere with the dominant character of the streetscape. He said that based on the proposed height, size, and location of the garage, it would be similar in appearance to several other garages on the street and would not result in a vehicle dominated frontage to the subject property or cause a break in the character of the street. He said the subject property is not a narrow lot and it can accommodate the proposed garage without dominating the frontage of the subject property. He stated that the proposed development conforms with all other standards in the Zoning By-law, including the applicable parking and setback standards.
24Mr. Sandercott opined that the proposed variance maintains the general purpose and intent of the Zoning By-law. He opined that the proposed variance would not change the dominant character of the street and, given the frontage of the subject property, the proposed garage would not dominate the street view of the subject property or detract from the front entrance of the dwelling. He stated that the proposed design of the garage is appropriate and the proposed development would appear from the street as being secondary in nature to the existing dwelling.
25Ms. Wright stated that the proposed variance does not maintain the general purpose and intent of the Zoning By-law. She said that it would build upon a minor development pattern of attached garages and result in an increase in that type of garage. She said it sets a poor precedent and defeats the intent of the Zoning By-law.
26Ms. Guher stated that the proposed variance would result in over-development on the subject property and agreed with Ms. Wright that it would set a poor precedent for the area.
27Mr. Lemay also stated that the proposed variance does not maintain the general purpose and intent of the Zoning By-law. He stated that the Zoning By-law removes subjectivity when zoning decisions are made and that this methodical process should be respected. He further stated that front-facing attached garages are prohibited in the immediate area surrounding the subject property and that this requirement must be enforced.
28In her Participant statement, Ms. Walsh submitted that, based on the Appellant’s Streetscape Character Analysis, the proposed variance would facilitate the development of a garage that is prohibited under the Zoning By-law. She submitted that the Zoning By-law ensures compatible development in mature neighbourhoods and the proposed attached garage would alter the streetscape character of the area.
Analysis and Findings
29The Tribunal finds that the proposed variance maintains the general purpose and intent of the Zoning By-law. Based on the development plans proposed by the Appellant, the Tribunal finds that the proposed variance would not change the dominant character of the street and the proposed garage would not unduly alter the streetscape. The Tribunal finds that the proposed garage would be secondary in nature to the existing dwelling and would be similar in appearance to other garages on the street. It finds that although the proposed development would not be exactly the same as the prevalent detached form of garage in the immediate vicinity of the subject property, given the frontage of the subject property, and the proposed height, size, and location of the proposed garage, the proposed garage would be very similar to others in the area and it would be in keeping with the character of the area. It finds that the proposed variance will not facilitate a development resulting in a vehicle-dominated frontage, impact the principal entranceway to the dwelling, or impact the view of it from the street.
Issue 3 Is the proposed variance desirable for the appropriate use of the subject property?
Evidence and Submissions
30Mr. Chown opined that the proposed variance is desirable for the appropriate use of the subject property. He stated that the construction of an addition to the existing dwelling is permitted on the subject property as of right, which would be similar in form and size to the proposed garage, but closer to the street. He opined that the proposed variance represents good planning.
31Mr. Sandercott supported Mr. Chown’s opinion that the proposed variance is desirable for the appropriate use of the subject property. He said it represents good planning based on the proposed height, size, and position of the proposed garage and because the proposed garage would be secondary in nature. He opined that the proposed variance is in the public interest based on the proposed design of the garage.
32Ms. Wright stated that the proposed variance does not have the support of neighbours and is not desirable for the appropriate use of the subject property. She stated that no clear information has been provided regarding why an attached garage is necessary on the subject property. She said there is undue pressure on the community for re-development and a need to protect mature neighbourhoods.
33Ms. Guher stated that the Appellant’s proposed developments on the subject property, including the construction of an approved coach house (which is not the subject matter of this proceeding), would result in the loss of trees and privacy and cause drainage problems that will impact her property. She stated that this is not an appropriate use of the subject property.
34Mr. Lemay stated that the proposed variance is not desirable for the appropriate use of the subject property as it would facilitate a development that is out of character for the area.
Analysis and Findings
35The Tribunal finds that the proposed variance is desirable for the appropriate use of the subject property. The Tribunal finds that based on the proposed height, size, and position of the proposed garage as set out in the Appellant’s proposed development plans and, based on its secondary nature, the proposed variance represents good planning and is in the public interest.
Issue 4 Is the proposed variance minor?
36Mr. Chown opined that the proposed variance is minor. He stated that the proposed variance would not result in any undue adverse impacts on neighbouring properties or the streetscape and the proposed development would not dominant the streetscape or the frontage of the subject property.
37Mr. Sandercott also opined that the proposed variance is minor. He agreed with Mr. Chown that it would not result in undue adverse impacts on the streetscape or abutting properties.
38Ms. Wright stated that the proposed variance would have the impact of diminishing the effectiveness of the Zoning By-law.
39Ms. Guher stated that the Appellant’s proposed development would result in the loss of trees and cause drainage problems that would impact her property and result in the loss of shade and privacy.
40Mr. Lemay stated that the proposed variance is not minor as it would impact the planning context of the area and erode the streetscape character of the area. He also raised drainage concerns and the need for a fence between his property and the subject property.
41In his Participant statement, Mr. van Wesenbeeck stated that the proposed variance is not minor and would result in the loss of trees and privacy.
Analysis and Findings
42The Tribunal finds that the proposed variance is minor. The evidence before the Tribunal is that the proposed variance will facilitate a front-facing attached garage that does not have any identifiable undue adverse impacts on the streetscape, neighbourhood, or neighbouring properties. Ms. Guher and Mr. Lemay expressed concerns regarding drainage, the loss of trees, privacy, and shadowing, but failed to demonstrate how the proposed variance for an attached garage would result in development that would cause any of these impacts.
The PPS and s. 2 of the Planning Act
43Mr. Chown opined that the proposed variance is consistent with the PPS. He also stated that he has had regard to the matters of provincial interest set out in s. 2 of the Planning Act. Mr. Sandercott supported Mr. Chown’s opinions regarding consistency with the PPS and in regard to matters of provincial interest.
Analysis and Findings
44Based on the opinions of Mr. Chown and Mr. Sandercott, the Tribunal finds that the proposed variance is consistent with the PPS. The Tribunal has had regard to the matters of provincial interest set out in s. 2 of the Planning Act and, as required under s. 2.1(1) of the Planning Act, it has had regard to the decision of the City’s Committee of Adjustment and the information considered by it.
Conclusions
45Based on the Appellant’s proposed development plans, the Tribunal finds that the proposed variance satisfies the four tests in s. 45(1) of the Planning Act, is consistent with the PPS, and constitutes good planning. The Tribunal has had regard to the matters of provincial interest in s. 2 of the Planning Act and the decision of the Committee of Adjustment regarding this matter and the information that the Committee had before it.
ORDER
46The Tribunal orders that the appeal is allowed and the variance to By-law No. 2008-250 is authorized subject to the location, height, and size of the proposed development being in accordance with the site plan drawings attached to this Order and Decision as Schedule 1.
“Hugh S. Wilkins”
HUGH S. WILKINS
MEMBER
Ontario Land Tribunal
Website: olt.gov.on.ca Telephone: 416-212-6349 Toll Free: 1-866-448-2248
The Conservation Review Board, the Environmental Review Tribunal, the Local Planning Appeal Tribunal and the Mining and Lands Tribunal are amalgamated and continued as the Ontario Land Tribunal (“Tribunal”). Any reference to the preceding tribunals or the former Ontario Municipal Board is deemed to be a reference to the Tribunal.
LOT 133
LOT 134
ZONING - R1QQ
PRINCIPAL D.U. COACH HOUSE
GENERAL NOTES (2) - PART 9
0 - GENERAL REQUIREMENTS:
LOT 132
MIN. LOT WIDTH - MIN. LOT AREA-
REQUIRED 12.0m
360m²
REQUIRED
PROVIDED 14.035m
416.73m²
0.1 - DRAWINGS NOT TO BE USED FOR PERMIT OR CONSTRUCTION UNLESS SEAL IS SIGNED BY ARCHITECT.
OHU 0.1E
FENCE
0.2m HIGH TIMBER RETAINING WALL PER CITY OF OTTAWA STANDARD DWG L8
TOP OF WALL=72.10
FENCE
FENCE
FENCE
BUILDING AREA
N/A
50m²
111.96m² (PRINCIPAL D.U. & GARAGE)
35.61m² (COACH HOUSE )
1 - STRUCTURAL:
OHU 0.3E
±TO LINE
0.09S
0.06N, 0.14N
0.06E/W TO LINE N/S
MAX. LOT COVERAGE-
60%
26.86% (PRINCIPAL D.U. & REC. RM.)
1.1 -
1.2 -
1.3 -
1.4 -
STEEL, TIMBER AND BUILT-UP TIMBER COLUMNS FROM ALL LEVELS SHALL BE CARRIED DOWN TO THE FOUNDATION OR TO SUPPORTING BEAMS, PROVIDE BLOCKING WHERE REQUIRED. STEEL COLUMN PLATES TO BE ANCHORED TO FOOTINGS AND BEAM FLANGES.
ALL LOAD BEARING WALLS, COLUMNS, ARCHES, IN THE STOREY IMMEDIATELY BELOW A FLOOR ASSEMBLY SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN THAT REQUIRED FOR THE SUPPORTED FLOOR ASSEMBLY.
PRE-ENGINEERED TIMBER TRUSSES TO BE DESIGNED BY TRUSS MANUFACTURER, RESPONSIBILITY FOR THE DESIGN RESTS WITH THE CONTRACTOR, SUBMIT SHOP DRAWINGS FOR REVIEW.
FLOOR FRAMING SYSTEM TO BE AS PER MANFACTURE STANDARD DETAILS AND SPECIFICATIONS.
PROPOSED
1 STOREY COACH HOUSE 35.61m²
w/ CRAWL SPACE
HP
7.25
BOARD FENCE
N 66°31'40" E
14.03
EXISTING SUMP PUMP DISCHARGE
(1.5m MIN. FROM PROPERTY LINE)
WOOD STEP
LOT 141
P.T. WOOD DECK 10' x 6'
5.79
1.00
OVERHEAD HYDRO/TELE CABLE
PROPOSED
1 STOREY COACH HOUSE
MAX. BUILDING HEIGHT - MIN. FRONT YARD -
MAX. EXTERIOR SIDE YARD - MIN. REAR YARD -
REAR YARD AREA -
11.0m
3.0m
3.0m
8.91m
25% LOT AREA
3.6m
4.0m
N/A
8.54% (COACH HOUSE )
7.831m (PRINCIPAL D.U.)
3.58m (COACH HOUSE )
6.13m
N/A
10.56m (PRINCIPAL D.U.)
4.0m (COACH HOUSE )
147.95m² (35.50%)
M. David Blakely Architect Inc.
2200 Prince of Wales Dr. - Suite 101 Ottawa, Ontario K2E 6Z9
Phone (613) 226-8811 Fax (613) 226-7942
GENERAL NOTES:
1 - THE CONTRACTOR IS RESPONSIBLE FOR CHECKING
2 - SITEWORK:
72.30
ROOF OVERHANG
72.30
35.61m²
w/ CRAWL SPACE
MAX. AREA OF COACH HOUSE
AND VERIFYING ALL DIMENSIONS, ANY DISCREPANCY
MUST BE REPORTED TO M. DAVID BLAKELY ARCHITECT Inc.
2.1 -
DRAINAGE: MAINTAIN EXISTING OVERALL SITE DRAINAGE AWAY FROM PERIMETER OF NEW FOUNDATIONS. WATERPROOFING TO BE 3mm RUBBERIZED ASPHALT APPLIED TO EXTERIOR FACE OF FOUNDATION WALLS, INCLUDING WALLS BETWEEN HOUSE AND GARAGE TO EXTEND FROM GRADE TO TOP OF FOOTING ( 2 COATS).
5.79
0.39
T.O. FND= 72.70 USF= 71.08
T.O. F.F. =72.70
IN REAR YARD
MIN. INTERIOR SIDE YARD -
1.2m
50%
24.07% (42.76m²)
0.8m (EXISTING HOUSE)
1.33m ( REC. RM. ADDITION)
2 - ALL WORK AND MATERIALS TO BE IN COMPLAINCE WITH ALL CODES, REGULATIONS, & BY-LAWS
3 - ADDITIONAL DRAWINGS MAY BE ISSUED FOR CLARIFICATION TO ASSIST THE PROPER EXECUTION OF WORK. SUCH DRAWINGS WILL
WATER & SANITARY, AND HYDRO/BELL SERVICE TO CONNECT TO THE PRINCIPAL BUILDING.
WATER AND SANITARY SERVICES TO BE INSULATED PER CITY OF OTTAWA SPECIFICATION W22.
WATER SUPPLY (HEATING/POTABLE) TO BE INSTALLED IN THE ECOFLEX PRE-INSULATED THERMAL PIPE SYSTEM IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS.
SANITARY SERVICE TO BE 75mm DIA. ABS PIPE @ 1% MIN. SLOPE.
WATER SERVICE TO BE 19mm PEX PIPE.
SAN SERVICE INV. @ BUILD = 71.07
SAN SERVICE INV. @ COACH HOUSE = 71.11 WATER SERVICE TOP @ BUILDING = 71.10 WATER SERVICE TOP @ COACH HOUSE = 71.10
3 - CONCRETE:
CONNECT FOUNDATION DRAIN FROM THE COACH HOUSE TO THE
1.0m
1.0m (COACH HOUSE)
HAVE THE SAME MEANING AND INTENT AS IF THEY WERE INCLUDED WITH THE PLANS IN CONTRACT DOCUMENTS
3.1 -
CONCRETE TO BE 20 MPa @ 28 DAYS FOR FOOTINGS AND WALLS, CONCRETE FOR PORCH SLAB TO 32 MPa(MIN.) @ 28 DAYS 6 % (+/- 1 %) AIR ENTRAINMENT 0.45 WATER / CEMENT RATIO, BROOM FINISH. BASEMENT CONCRETE SLAB 25 MPa @ 28 DAYS.
EXISTING FOUNDATION DRAIN AT
THE ADDITION.
DIA=0.25
SHALLOW DRAINAGE SWALE (0.15m)
PARKING REQUIRED PER UNIT
1 SPACES
2 SPACES
4 - DO NOT SCALE DRAWINGS.
5 - THIS DRAWING SHALL NOT BE USED OR COPIED WITHOUT THE AUTHORIZATION OF THE ARCHITECT
6 - THIS DRAWING SHALL NOT BE USED FOR PERMIT
3.2 -
3.3 -
3.4 -
FOUNDATION WALL DRAINAGE AS PER O.B.C. 9.14.
MINIMUM BEARING CAPACITY USED IN FOOTING DESIGN IS 75 Kpa. BEARING SURFACE TO BE INSPECTED BY THE SOILS ENGINEER PRIOR TO THE PLACEMENT OF CONCRETE.
TYPICAL FOUNDATION WALL TO HAVE 2-10m BARS 4" FROM TOP & BOTTOM OF FOUNDATION
0.14(Bldg) EAVE ±TO LINE
1.00
R=4.0 T.B.R.
5.18
MIN. PARKING SPACE DIMENSIONS - 2.5m x 5.2m
PROPOSED AREA OF HARD LANDSCAPING- TOTAL SITE = 105.46m² REAR YARD = 48.92m²
OR CONSTRUCTION UNLESS THE DRAWING BEARS THE ARCHITECT'S SEAL AND SIGNATURE
7 - THIS REPRODUCTION SHALL NOT BE ALTERED.
72.55
4 - MASONRY:
EXISTING
2 STOREY BRICK
PROPOSED
GARAGE ADDITION
EXIST. SUMP PIT LOCATION
1.20
72.50
1.00
LIMITING DISTANCE LINE
FRONT YARD = 33.55m²
4.1 -
4.2 -
BRICK QUOINS, SOLDIER COURSES AND WINDOW SURROUNDS TO PROJECT 1/2" BEYOND REGULAR BRICK FACE, EXCEPT AS NOTED.
72.55
PROVIDE BRICK TIES AS PER O.B.C. 9.20.9. PROVIDE THRU BRICK FLASHINGS w/ WEEP HOLES ON FOUNDATION WALL, OVER ROOFS AND ON LINTELS.
DWELLING No. 57
19.40m²
PROPOSED
COURT YARD
72.52
EXISTING AVERAGE GRADE 72.51+72.78+72.45+72.46= 290.22
4.3 - WEEPHOLES TO BE PLACED AT 610mm (2'-0") o/c IN BOTTOM COURSES OF BRICK, AND OVER WINDOW AND DOOR HEADS.
COACH HOUSE SERVICE LOCATIONS
SCALE - N.T.S.
STEPS &
LANDING
VINYL
72.55
GARAGE T.B.R.
290.22/4= 72.55
72.55
EXISTING AVERAGE GRADE = 72.55m
5 - METALS:
LOT 142
5.1 - REINFORCING STEEL YIELD STRENGTH TO BE 60 K.S.I.
5.2 - PRIME AND PAINT EXPOSED STEEL LINTELS.
LOT 140
0.18(Bldg) EAVE ±TO LINE
1.20
0.46
0.92
3.94
3.58
4.90
1.33
GRADES AND SLOPES DERIVED FROM TOPOGRAPHIC DETAIL OF
LOT 141 REGISTERED PLAN No. 222921
6 - WOOD (FRAMING) AND PLASTICS:
EXISTING
CITY OF OTTAWA
PREPARED BY J.D. BARNES LIMITED
6.1 -
6.2 -
6.3 -
6.4 -
6.5 -
6.6 -
6.7 -
6.8 -
6.9 -
6.10 -
6.11 -
6.12 -
6.13 -
6.14 -
LUMBER TO BE SPF #2 OR BETTER, EXCEPT PORCH POST TO BE PRESSURE TREATED PINE. ALL BEAMS TO BE FLUSH EXCEPT AS NOTED.
BEAMS NOTED AS 'LVL' ARE LAMINATED VENEER LUMBER. SIZES ARE BASED ON THE USE OF TRUSS, JOIST PRODUCTS AND ALTERNATES ARE ACCEPTABLE IF CAPACITY MEETS THOSE SPECIFIED ON THESE DRAWINGS NOTCHING AND DRILLING SHALL COMPLY TO 9.23.5 O.B.C..
PROVIDE 38mm x 38mm (1 1/2" x 1 1/2") CROSS BRIDGING AT FLOOR JOIST @ 2,085mm (6'-10") MAX. o/c. FLOOR JOISTS OR BLOCKING UNDER ALL PARALLEL PARTITIONS.
SUB- FLOOR TO BE 15.9mm (5/8") T&G PLYWOOD GLUED AND SCREWED. CUSHION FLOORING TO HAVE 6.5mm (1/4") POPLAR UNDERLAY.
PROVIDE BLOCKING FOR FUTURE GRAB BARS IN MAIN BATHROOM AT TOILET AND TUB IN LOCATIONS REQUIRED BY O.B.C. 3.8.3.8 (1)(d) AND 3.8.3.13 (1)(f).
EXTERIOR WINDOW AND DOOR LINTEL TO BE 3-2x10, EXCEPT AS NOTED.
ALL INTERIOR PARTITIONS TO BE 12.8mm (1/2") GYPSUM BOARD ON BOTH SIDES OF 38mm x 98mm(2"x4") OR 38mm x 150mm (2"x6") STUDS @ 410mm (16") O.C.
FINISHED WITH TAPE AND PLASTERED JOINTS, UNLESS NOTED OTHERWISE.
STAIRS: MAX. 200mm (7 7/8") RISE (PRIVATE), MAX. 180mm (7 3/32") RISE (PUBLIC) MIN. 210mm (8 1/4") RUN (PRIVATE), MIN. 280mm (11") RUN (PUBLIC)
MIN. 235mm (9 1/4") TREAD (PRIVATE), MIN. 280mm (11") TREAD( PUBLIC) HANDRAILS TO BE 865mm (2'-10") TO 965mm (3'-2") HIGH
PROVIDE MIN. 1,950mm (6'-5") HEADROOM CLEARANCE ON STAIRS SERVING 1 DWELLING UNIT, 2,050mm (6'-9") FOR OTHER.
0.44
0.64
0.64
0.89
DOWNSPOUT
EXISTING
2 STOREY BRICK DWELLING
No. 57
EXISTING DOWNSPOUT
PROPOSED DOWNSPOUT
EXISTING DOWNSPOUT TO BE RELOCATED
TOW ELEV=73.55
8.24
PROPOSED GARAGE ADDITION 19.79m²
T.O. FND= 72.75 USF= 71.39
T.O. FLR. SLAB =72.60
3.58
DS ELEV=73.06
72.60
ROOF OVERHANG
1.20
1.33
DATED:
SITE BOUNRDIES DERIVED FROM SURVEYOR'S REAL PROPERTY REPORT
PART 1 - PLAN SHOWING LOT 141 REGISTERED PLAN No. 222921 CITY OF OTTAWA
PREPARED BY J.D. BARNES LIMITED DATED:
SURVEYOR TO VERIFY SETBACKS, ZONING REQUIREMENTS & EASEMENTS BEFORE SETTING-OUT FOR CONSTRUCTION.
LIST OF DRAWINGS
A0 INDEX & OBC/ SB12 / SITE & GRADING PLAN
7 - THERMAL AND MOISTURE PROTECTION:
4.91
FLOOR PLANS:
7.1 -
7.2 -
7.3 -
7.4 -
7.5 -
MOISTURE BARRIER SHALL BE PROVIDED IN ALL AREAS WHERE WOOD IS IN CONTACT WITH CONCRETE OR UNIT MASONRY.
ALL POLY VAPOUR / AIR BARRIER TO CONFORM TO CGSB-51.34 CAULK AND SEAL ALL JOINTS w/ 100mm (4") min. LAP JOINTS.
CAULK PERIMETERS, INSIDE AND OUTSIDE OF EXTERIOR DOORS AND WINDOWS. SERVICES PENETRATING A FIRE SEPARATION (RATED ASSEMBLY) SHALL CONFORM TO
9.10.9.6 AND 9.10.9.7. O.B.C
FLASHING TO BE PRE-FINISHED METAL. APPLY AT EXPOSED DOOR / WINDOW HEADS AND SILLS,
14.035
ROOF VALLEYS, CHIMNEY / ROOF CONNECTIONS, HIGH WALL / ROOF CONNECTIONS, CHIMNEY CAPS, SKYLIGHT PERIMETERS, U/S OF BRICK AND AS SHOWN ON DRAWINGS.
INTERLOCK PATHWAY
1.20
A1 BASEMENT & GROUND FLOOR PLANS
ELEVATIONS:
A2 SOUTH & EAST ELEVATIONS A3 NORTH & WEST ELEVATIONS
07/09/21 REVISED FOR PROPOSED GARAGE ADDITION JB
7.6 -
7.7 -
FIRE BLOCKING SHALL CONFORM TO SECTIONS 9.10.16. O.B.C..
EIFS - DUROCK PUCCS SYSTEM TO BE INSTALLED AS PER MANUFACTURERS
EXISTING TREE
SECTIONS:
09/08/21 REVISED PER CITY COMMENTS JB
05/07/21 FOR PERMIT JB
SPECIFICATIONS & DETAILS
8 - DOORS AND WINDOWS:
A4 SECTIONS & DETAILS
18/05/21 FOR CLIENT & STRUCTURAL REVIEW JB
26/04/21 REVISED COACH HOUSE JB
26/04/21 REVISED COACH HOUSE OPTION JB
8.1
14.035
N 66°28'30" E
14.035
APPLIED WINDOW MUNTIN BARS TO BE WHERE SHOWN ON ELEVATIONS.
8.2 - GARAGE MAN-DOOR SHALL BE EXTERIOR - TYPE, SELF CLOSING AND WEATHERSTRIPPED.
ELECTRICAL:
23/03/21 FOR COACH HOUSE OPTION JB
22/03/21 REAR YARD SETBACK REVISED JB
9 - FINISHES:
CONCRETE SIDEWWALK
E1 ELECTRICAL LAYOUT
15/03/21 GARAGE REMOVED JB
20/01/21 REVISED PER CITY COMMENTS JB
9.1 -
9.2 -
9.3 -
9.4 -
OAK HANDRAIL AND SPINDLES FOR ALL STAIRS, EXCEPT BASEMENT STAIR (U/N OTHERWISE). COMPLY TO 9.8. O.B.C.
FOR CERAMIC TILE FLOORING PROVIDE CERAMIC TILE ADHESIVE AS PER MANUFACTURERS RECOMMENDATIONS ON 15.9mm (5/8") PLYWOOD UNLAY.
FINISH FLOORING IN BATHROOMS, KITCHENS, LAUNDRY ROOMS AND ENTRANCES SHALL BE WATER RESISTANT.
FINISHES, FIXTURES, MILLWORK AND WOOD STAIRS TO CLIENTS REQUIREMENTS.
MH_STM
SITE BENCHMARK
TOP OF STORM MANHOLE LID ELEV=74.17
3.10 +/- (EXISTING)
H U T C H I S O N A V E .
16/12/20 GARAGE/ IN-LAW SUITE FOR PERMIT JB
27/03/19 PER CITY COMMENTS JB
26/03/19 PER CITY COMMENTS JB
12/03/19 FOR PERMIT JB
13/02/19 REVISED PER COMMENTS JB
06/02/19 FOR REVIEW JB
9.5 -
9.6 -
9.7 -
9.8 -
ALL WALL CABINETS IN KITCHEN/LAUNDRY TO HAVE DROPPED BULKHEADS ABOVE UNLESS NOTED. INTERIOR TRIM, BASEBOARDS, CASING AND ALL SWING DOORS TO BE COLONIAL.
GYPSUM BOARD AT BATHTUB AND SHOWER WALLS TO BE WATER RESISTANT.
ALL BATH TUB AND SHOWER ENCLOSURES TO HAVE 250mm (10") DROPPED CEILING AND CERAMIC TILE FINISH UNLESS NOTED OTHERWISE.
SITE & GRADING PLAN
SCALE - 1:150
SCALE:
0 10
5 15
DATE:
A
DESCRIPTION
R E V I S I O N S
A - DETAIL NUMBER B - SHEET NUMBER
Int.
10 - SPECIALTIES:
(DETAIL REQUIRED)
10.1 -
10.2 -
10.3 -
PROVIDE BATHROOM ACCESSORIES, SHOWER ROD, SOAP HOLDER, TOILET PAPER HOLDER, TOWEL BAR, RECESSED MEDICINE CABINET AND GRAB BARS WHERE SHOWN.
ALL ENSUITE AND BATHROOMS TO HAVE RECESSED MEDICINE CABINET IN INTERIOR WALLS AND SURFACE MOUNTED ON EXTERIOR WALLS.
VANITY MIRRORS FULL WIDTH OF VANITY BY 765mm (30") HIGH.
COACH HOUSE
B C
SEAL:
C - SHEET NUMBER (DETAIL LOCATION)
11 - MECHANICAL/ ELECTRICAL:
Firm Name: M. DAVID BLAKELY ARCHITECT INC.
ENERGY EFFICIENT DESIGN
Firm Name: M. DAVID BLAKELY ARCHITECT INC.
11.1 - PROVIDE VENTILATION AS PER O.B.C. 9.32..
11.2 - DEDICATED HRV (WITH TIMERS) CONNECTED TO ALL BATHROOMS.
Certificate of Practice Number:
3644
SB-12 - 2.1.1.2.A
PACKAGE - A1
Certificate of Practice Number:
3644
11.3 -
11.4 -
11.5 -
11.6 -
11.7 -
11.8 -
11.9 -
11.10 -
11.12 -
INSTALL SMOKE ALARMS AS PER O.B.C. 9.10.19., SMOKE ALARMS SHALL BE PROVIDED WHERE SHOWN, IN ALL BEDROOMS AND TO BE INTERCONNECTED.
CARBON MONOXIDE DETECTOR, INSTALLED ON CEILING, WIRED DIRECT TO ELECTRICAL PANEL, ALSO WIRED TO SMOKE ALARMS.
PROVIDE ROUGH-IN FOR SECURITY AND CENTRAL VAC SYSTEM.
HEATING AND VENTILATION SYSTEM TO BE DESIGNED BY BUILDERS DESIGN - BUILD CONTRACTOR. DESIGN LAYOUT TO BE PROVIDED FOR REVIEW.
DRYER EXHAUST VENT DUCT SYSTEM SHALL CONFORM WITH PART 6. OUTDOOR INTAKE/EXHAUST VENTS SHALL CONFORM O.B.C. 9.32.3.12.
PROVIDE ELECTRICAL AND PLUMBING CONNECTIONS FOR DISH-WASHER, CLOTHES WASHER AND DRYER. APPLIANCES N.I.C., HOT WATER TANKS ARE RENTALS.
GAS FURNACES TO BE HIGH EFFICIENCY, GAS FIRED C/W DIRECT VENT. AS PER O.B.C. TABLE 2.1.1.2.A. IF APPLICABLE, MATERIALS USED IN PLENUM SHALL HAVE MAX. FLAME SPREAD OF 25, AND A SMOKE
2200 PRINCE OF WALES DRIVE , SUITE 101
Ottawa, Ontario, K2E 6Z9
Name of Project: 57 HUTCHISON AVE.
PROPOSED GARAGE ADDITION
Location: Ottawa, Ontario
PERIPHERAL WALL AREA = 779.17 sq.ft. (72.39m² ) AREA OF WINDOWS, SIDELITES, GLASS IN
DOORS AND PATIO DOORS = 91.90 ft² (8.53m² )
% WINDOWS = 11.78 % ( 17 % Max. )
CEILING WITH ATTIC - R-60
WALLS ABOVE GRADE - R-22 ( R-22+ 5ci PROVIDED) BASEMENT WALLS - 20ci (R-12 + R-10ci PROVIDED)
WINDOWS & SLIDING GLASS DOORS - U = 0.28 Max FURNACE - Min AFUE = 96 %
2200 PRINCE OF WALES DRIVE , SUITE 101
Ottawa, Ontario, K2E 6Z9
Name of Project: 57 HUTCHISON AVE.
PROPOSED COACH HOUSE
Location: Ottawa, Ontario
11.13 -
DEVELOPMENT OF 50.
FIREPLACES TO BE HIGH EFFICIENCY GAS , DIRECT VENT, TO BE INSTALLED AS PER MANUFACTURERS
Index Ontario's 2012 Building Code Data Matrix Parts 3 & 9
OBC Reference
HRV - Min EFFICIENCY = 75 %
Index Ontario's 2012 Building Code Data Matrix Parts 3 & 9
OBC Reference
PROJECT:
11.14 -
11.15 -
RECOMMENDATIONS, FIREPLACE HEARTHS TO BE CERAMIC TILE.
DRAIN WATER HEAT RECOVERY SYSTEM DWHR - MINIMUM EFFICIENCY 42%.
PROVIDE ROUGH-IN FOR ELECTRICAL VEHICLE CHARGING STATION AS PER O.B.C. 9.34.4.1.
- Project Description:
1 Storey Garage Addition to 2 Storey Detached Dwelling
New Addition Alteration
Part 11
11.1 to 11.4
Part 3
1.1.2. [A]
Part 9
1.1.2. [A] 9.10.1.3
HOT WATER HEATER - Min EFFICIENCY = 0.80 DWHR - Min EFFICIENCY = 42%
- Project Description:
2 Storey
Detached Dwelling
New Addition Alteration
Part 11
11.1 to 11.4
Part 3
1.1.2. [A]
Part 9
1.1.2. [A] 9.10.1.3
MOROZ RESIDENCE 57 HUTCHISON AVE. OTTAWA, ONTARIO
GARAGE ADDITION & COACH HOUSE
CLIENT:
PETER MOROZ
DRAWING TITLE:
57 HUTCHISON AVE.
SITE & GRADING PLAN GENERAL NOTES, MATRIX & LIST OF DWG'S
DATE:
MAY, 2021
SCALE:
AS NOTED
DRAWN BY:
JB
CHECKED:
MDB
A0
1'-0"
1'-0"
M. David Blakely Architect Inc.
2200 Prince of Wales Dr. - Suite 101 Ottawa, Ontario K2E 6Z9
Phone (613) 226-8811 Fax (613) 226-7942
12 12
10 10
T.O. ATTIC JOISTS
EXIS
T.
70" x
50"
U/S CEILING
12
10
EXIST. 45" x 27"
T.O. SECOND FLOOR
ASPHALT SHINGLES
12 ALUMINUM FASCIA
3
& SOFFIT(VENTED)
T.O. PLATE
VALLEY FLASHING
ASPHALT SHINGLES 12
ALUMINUM FASCIA
& SOFFIT(VENTED) 5
T.O. PLATE
12
12 5
5
3'-31"
2
[1.0m]
ROOF VENTS
ASPHALT SHINGLES ALUMINUM FASCIA & SOFFIT(VENTED)
2
1'-31"
96"
T.O. GROUND FLOOR
T.O. FND. WALL @ FRONT
EXIST. 45" x 39"
1'-0"
FLASHING
CORNER TRIM
VINYL SIDING 4" SUUROUND
ALUMINUM TRIM
CORNER TRIM VINYL SIDING
PRECAST SILL BRICK VENEER
2'-0"
2'-0"
EXIS
T.
70" x
50"
34" x
2'-0"
[ 0.390 m ]
ALUMINUM TRIM
CORNER TRIM VINYL SIDING
PRECAST SILL BRICK VENEER
T.O. BASEMENT FLOOR
72.78
EXISTING HOUSE
NEW PORCH, STEPS & RAILING
72.60
2
PROPOSED ADDITION (11'-81")
PARGING
2'-0"
T.O. NEW FND . WALL
T.O. FLOOR SLAB
71 .39 U/S FOOTING
2" HI. RIGID INSULATION
AS REQ'D BY GEOTECH ENG.
72.55
EXISTING AVERAGE GRADE
T.O. N EW FND. WALL 72.70
72.50
71.08
72.55
BRICK AREA= 31 ft² BRICK AREA= 7 ft²
AREA OF EXPOSED BUILDING FACE= 182 ft² AREA OF U.P.O. = 5.6 ft²
% U.P.O. = 3.0%
SOUTH (FRONT) ELEVATION - COACH HOUSE
SCALE- 3/16" = 1'-0"
72.50
PARGING
SOUTH (FRONT) ELEVATION
SCALE- 3/16" = 1'-0"
T.O. ATTIC JOISTS
U/S CEILING
1'-0"
12
10
12
10
12
10
FLASHING SET INTO REGLET
12
10
12
10
30" x 54" EXIST.
2'-0"
EXISTING 2 STOREY ADDITION BEYOND NEW P.T. WOOD DECK
07/09/21
REVISED FOR PROPOSED GARAGE ADDITION
JB
05/07/21
PER STRUCTURAL / FOR PERMIT
JB
18/05/21
FOR CLIENT & STRUCTURAL REVIEW
JB
DATE:
DESCRIPTION
Int.
R E V I S I O N S
36" HIGH P.T. WOOD GUARD
P.T. 2x4 CAP
P.T. 2x6
P.T. 1 1/2 x 1 1/2 PICKETS @ 5" o/c
P.T. 2x6 DECKING
P.T. 2x8 @ 16" o/c
P.T. 2-2x8
P.T. 6x6 POST
T.O. SECOND FLOOR
EXIST. 47" x 20"
T.O. PLATE
12
3
1'-0"
EXIST. 45" x 37"
12
FILL IN WINDOW @ EXISTING HOUSE
3
1'-0"
12
EXIST. 60" X 84"
ALUMINUM FASCIA & SOFFIT(VENTED)
5
2'-0"
12
5 12
5
12
5
2'-0"
ROOF VENTS
SEAL:
ASPHALT SHINGLES ALUMINUM FASCIA & SOFFIT(VENTED)
T.O. PLATE
T.O. GROUND FLOOR
T.O. FND. WA LL @ FRONT 73.35
72.78
T.O. BASEMENT FLOOR
73.55
T.O. NEW FND. WALL
T.O. FLOOR SLAB 72.60
71.39
EXISTING DOOR
73.06
FILL IN WINDOW
@ EXISTING HOUSE
VINYL SIDING PARGING
2
CORNER TRIM 18'-51" [5.63m]
72.55
72.60
30" x 66" EXIST.
72.55
72.50
PARGING
2" HI. RIGID INSULATION
AS REQ'D BY GEOTECH ENG.
ALUMINUM TRIM VINYL SIDING
CORNER TRIM
72.30
71.08
P.T. 2x6 DECKING
P.T. 2x8 @ 16" o/c
P.T. 2-2x8
P.T. 6x6 POST
72.70 T.O. NEW FND . WALL
72.55
CLIENT:
PETER MOROZ
EXISTING AVERAGE GRADE
EAST (SIDE) ELEVATION
CHECKED:
MDB
DRAWN BY:
JB
A2
SCALE- 3/16" = 1'-0"
2" HI. RIGID INSULATION
AS REQ'D BY GEOTECH ENG.
12'-5" [3.8m]
FOOTINGS TO BE ON UNDISTURBED SOIL & INSULATED AS PER GEOTECHNICAL ENGINEERS RECOMMENDATIONS
12
12
10
10
12
12
10
10
FLASHING
12
10
FLASHING
ROOF VENTS
M. David Blakely Architect Inc.
2200 Prince of Wales Dr. - Suite 101 Ottawa, Ontario K2E 6Z9
Phone (613) 226-8811 Fax (613) 226-7942
ASPHALT SHINGLES
VALLEY FLASHING ALUMINUM FASCIA & SOFFIT(VENTED)
T.O . ATTIC JOISTS U/S CEILING
EXIST. 45" x 51"
2'-0"
24"
EXIST.
66" x 54"
EXI
ST.
24" x 54"
2'-0"
ASPHALT SHINGLES 12
1
A3
FLASHING
4" SURROUND
CORNER TRIM VINYL SIDING
T.O. SECOND FLOOR
12 12
5 5
2'-0"
24" x 24"
ROOF VENTS
12
5 ASPHALT SHINGLES
ALUMINUM FASCIA
& SOFFIT(VENTED)
T.O. PLATE
ALUMINUM FASCIA & SOFFIT(VENTED)
VINYL SIDING
CORNER TRIM 4" SURROUND
3
1'-0"
FLASHING
6"
73.55
EXIST. 45" x 39"
73.55
NEW P.T. WOOD DECK
T.O. FENCE
74.53
EXIST. 24" x 66"
FLASHING
4" SURROUND
VINYL SIDING CORNER TRIM
T.O. GROUND FLOOR
73.35 T.O. FND. WALL @ FRONT
T.O. PLATE
2
1'-31"
[ 0.390 m ]
R.S.O. 25" X 25"
60" X 96" PATIO DR.
2'-0"
ALUMINUM TRIM VINYL SIDING
CORNER TRIM
72.75
T.O. NEW FND. WALL
PARGING
PARGING
T.O. FLOOR SLAB
71.39
72.75
INSULATE FOOTING AS REQ'D BY GEOTECH ENG.
72.60
72.55
INSULATE FOOTING
AS REQ'D BY GEOTECH ENG.
36" HIGH P.T. WOOD GUARD
P.T. 2x4 CAP
P.T. 2x6
P.T. 1 1/2 x 1 1/2 PICKETS @ 5" o/c
P.T. 2x6 DECKING
P.T. 2x8 @ 16" o/c
P.T. 2-2x8
P.T. 6x6 POST
72.55
PARGING
T.O. BASEM ENT FLOOR
72.55
EXISTING AVERAGE GRADE
T.O. NEW FND. WALL
72.50
72.70
71.08
P.T. 2x6 DECKING
P.T. 2x8 @ 16" o/c
P.T. 2-2x8
P.T. 6x6 POST
72.30
PROPOSED ADDITION (11'-9")
NORTH (REAR) ELEVATION - REC ROOM ADDITION
EXISTING HOUSE
2" HI. RIGID INSULATION
AS REQ'D BY GEOTECH ENG.
NORTH (REAR) ELEVATION - COACH HOUSE
SCALE- 3/16" = 1'-0"
FOOTINGS TO BE ON UNDISTURBED SOIL & INSULATED AS PER GEOTECHNICAL ENGINEERS RECOMMENDATIONS
SCALE- 3/16" = 1'-0"
FOOTINGS TO BE ON UNDISTURBED SOIL & INSULATED AS PER GEOTECHNICAL ENGINEERS RECOMMENDATIONS
12
10
12
10
30" x 54" EXIST.
2'-0"
ROOF VENTS
ASPHALT SHINGLES
VALLEY FLASHING ALUMINUM FASCIA & SOFFIT(VENTED)
T.O. PLATE
12
5
T.O. PLATE
FLASHING
12
5 12
5
1'-6"
R.S.O. 21" x 61"
12
5
24" x 60"
R.S.O. 25" x 61"
2'-0"
ROOF VENTS
07/09/21
REVISED FOR PROPOSED GARAGE ADDITION
JB
05/07/21
PER STRUCTURAL / FOR PERMIT
JB
18/05/21
FOR CLIENT & STRUCTURAL REVIEW
JB
DATE:
DESCRIPTION
Int.
R E V I S I O N S
ASPHALT SHINGLES ALUMINUM FASCIA & SOFFIT(VENTED)
ALUMINUM TRIM
CORNER TRIM VINYL SIDING
EXISTING EXTERIOR WALL
EXISTING EXTERIOR WALL
EXIST. 60" X 84"
30" x 66" EXIST.
VINYL SIDING 4" SURROUND
CORNER TRIM
T.O . SECOND FLOOR
FLASHING
4" SURROUND
VINYL SIDING
72.55
EXISTING AVERAGE GRADE
T.O. NEW FN D . WALL
72.70
72.30
71.08
PARGING
2" HI. RIGID INSULATION
AS REQ'D BY GEOTECH ENG.
72.55
BRICK AREA= 28 ft²
72.50
PRECAST SILL BRICK VENEER
SEAL:
A JOIST HANGER
A1 2x8 P.T. LEDGER BOARD
BOLTED TO FND. WALL
72.60
2-2x8 P.T.
CORNER TRIM
T.O. G RO UND FLOOR
T.O. NEW FND . WALL
PARGING
72.55
WEST (SIDE) ELEVATION - COACH HOUSE
SCALE- 3/16" = 1'-0"
INSULATE FOOTING AS REQ'D BY GEOTECH ENG.
PROJECT:
MOROZ RESIDENCE
DECK - SECTION
U/S NEW FOOTING
FOOTINGS TO BE ON UNDISTURBED SOIL OR AS PER GEOTECHNICAL ENGINEERS RECOMMENDATIONS
1
A1 A3
CLIENT:
57 HUTCHISON AVE. OTTAWA, ONTARIO
PETER MOROZ
DRAWING TITLE:
NORTH & WEST ELEVATIONS
DATE:
MAY, 2021
SCALE:
3/16" = 1'-0"
CHECKED:
MDB
A3

